Product Details:

Place of Origin: Chongqing, China
Brand Name: KATHER
Model Number: MCG8500DSE

Payment & Shipping Terms:

Minimum Order Quantity: 5 units
Price: $405.99/units 5-98 units
Get Best Price Contact Now

Detail Information

Warranty: 3months-1year Rated Voltage: 110V, 220V, 230V, 400V, 110/230V/400V
Rated Current: 28.3a Speed: 3600RPM
Frequency: 50hz/60hz Starting System: 24V DC Electric Start, 12V DC Electric Start, Recoil Start, Recoil /Electric Start
Product Name: MCG8500DSE 6.5kw Synchronous Gasoline Generator Engine Type: Single Cylinder,4-Stroke(OHV)
Displacement: 420cc Keywords: Portable Home Power Generators
Function: Portable Generator Provide Electric Power Color: Customer Required
Weight: 90kgs Package Size: 70x53x60cm

Product Description

6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 0
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 1
Product name
MCG8500DSE 6500w Synchronous Gasoline Generators
Engine Type
Single cylinder,4-Stroke(OHV)
Bore x Stroke (mm)
90x66
Displacement(cc)
420cc
Compression ratio
8.2:1
Rated Frequency(Hz)
50hz/60hz
Rated Voltage (v)
120/230V/400V
Rated Power (kw)
5kw/6.5kw/7.5KW/8kw/8.5kw/10kw
Rated current
28.3a
Starting System
Recoil/Electric start
Fuel Tank Capacity(L)
25L
Running Time (1/2 load ) (H)
7.5h
Noise (dB@7m)
78
Dimensions (L x W x H)(mm)
70X53X60cm
Weight (kg)
90KG
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 2
Precautions for using a generator:
1. Preheating and idling: When the engine temperature is low, the idling time should be appropriately extended for preheating, but when the temperature is normal, avoid long-term idling to avoid carbon deposits and oil leakage in the turbocharger and exhaust system. The load should be between 30% and 70% of the generator power. 2. Avoid overload: Do not let the generator run overloaded for a long time, which will cause failures and shorten the service life. 3. Maintenance and operation safety: It is strictly forbidden to disassemble or replace parts while the generator is running to prevent accidental injuries. 4. Coolant and antifreeze: Choose appropriate coolant or antifreeze according to the season and temperature, and pay attention to check the status of the water tank to avoid injuries caused by high-temperature liquid spraying. 5. Fuel management: Make sure to use fuel that meets the standards, be sure to turn off the generator when refueling, and do not smoke or approach open flames when refueling to prevent fuel overflow. 6. Check before starting: Check the fuel and oil levels before starting, ensure that the oil circuit is unobstructed and air-free, and connect the battery line and control module. 7. Fuel supply adjustment: Be careful when adjusting the fuel supply to avoid unstable operation or damage to the engine due to excessive fuel supply. Follow the comparison method for fine adjustment. 8. Environment and location: Place the generator in a well-ventilated location away from flammable materials. Avoid using it in a dusty environment to prevent malfunctions. 9. Fire safety: Understand and prepare appropriate fire extinguishing measures. In the event of a fire, follow specific emergency procedures, such as not using sand or foam fire extinguishers to directly extinguish the generator. 10. Regular maintenance: Perform regular inspections and maintenance according to the maintenance cycle recommended by the manufacturer, including replacing filters, engine oil, etc., to ensure that the generator is in the best condition. By following the above precautions, you can ensure the efficient, safe and long-term reliable operation of the silent generator.
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 3
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 4
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 5
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 6
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 7
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 8
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 9
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 10
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 11
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 12
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 13
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 14
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 15
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 16
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 17
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 18
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 19
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 20
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 21
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 22
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 23
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 24
6.5kW 6.5kVA 6500W Gasoline Generators for Processing 90kgs and Electric Recoil Start 25

Q1:Are you a factory or a trading company?

A:We are a factory.

Q2:What is the main products of your factory?

A:We are a factory.

Q3:Where is your factory located?

A:Agricultural railcar,Tiller&Cultivator,Generator,Water pump,Engine,Lawn Mower,Snow Blower,Rotary Tiller,Chainsaw,Garden Machinery,etc.

Q4:Do you support customization?What's the MOQ?

A:Of course, We have 15 years of production customization experience in OEM/ODM. 1 set

Q5:How can i order and make payment?

A:Once clear your requirement which product is ideal for you.We will send proformainvoice to you.You can pay via Trade Assurance,T/TBank,WesernUnion,Credit Card or Paypal as you like.

Q6:What are your payment terms?

A:T/T 30% deposit, 70% balance to be paid when the goods are ready. If you have special payment needs, please discuss with our sales staff first.

Q7:How long is your warranty?

A:1 year or 1000 hours warranty whichever comes first except the wearing and tearing parts.We suggest customers buy some wearing and tearing parts in each order.